FeatureSetUplink-v1800
TS 38.331
V18.5.1
2025-03
FeatureSetUplink-v1800 ::= SEQUENCE { -- R1 40-3-3-1a: Supported maximum delay value larger than D_basic maxDelayValueBeyondD-Basic-r18 ENUMERATED {sl2,sl3,sl4,sl5,sl6,sl10} OPTIONAL, -- R1 40-3-3-2: Number of delay values tdcp-NumberDelayValue-r18 INTEGER (2..4) OPTIONAL, -- R1 40-3-3-4: Phase report phaseReportMoreThanOne-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-3-3-6: Maximum number of TRS resource sets in a report configuration maxNumberTRS-ResourceSet-r18 INTEGER (2..3) OPTIONAL, -- R1 40-3-3-7: Maximum number of TDCP report settings per-BWP maxNumberTDCP-PerBWP-r18 INTEGER (1..4) OPTIONAL, -- R1 40-4-6c: DMRS type for Rel.18 enhanced DMRS ports for PUSCH pusch-DMRS-TypeEnh-r18 SEQUENCE { dmrs-Type-r18 ENUMERATED {etype1, both}, pusch-TypeA-DMRS-r18 SEQUENCE { -- R1 40-4-6: Basic feature of Rel.18 enhanced DMRS ports for PUSCH for scheduling mapping of type A for Rel.18 enhanced -- DMRS ports dmrs-TypeA-r18 ENUMERATED {supported}, -- R1 40-4-6d: 2 symbols front-loaded DMRS (uplink) for Rel.18 enhanced DMRS ports for PUSCH pusch-2SymbolFL-DMRS-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-4-6e: 2-symbol FL DMRS + one additional 2-symbols DMRS for Rel.18 enhanced DMRS ports for PUSCH pusch-2SymbolFL-DMRS-Addition2Symbol-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-4-6f: 1 symbol FL DMRS and 3 additional DMRS symbols for Rel.18 enhanced DMRS ports for PUSCH pusch-1SymbolFL-DMRS-Addition3Symbol-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-4-6k: 1 symbol FL DMRS and 2 additional DMRS symbols for more than one port for Rel.18 enhanced DMRS ports for -- PUSCH pusch-1SymbolFL-DMRS-BeyondOnePort-r18 ENUMERATED {supported} OPTIONAL } OPTIONAL, -- R1 40-4-10: DMRS port configuration for PUSCH with 8Tx dummy ENUMERATED {rel15, both} OPTIONAL, -- R1 40-4-6a: Basic feature of Rel.18 enhanced DMRS ports for PUSCH for scheduling type B for Rel.18 enhanced DMRS ports pusch-TypeB-DMRS-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-4-6g: 1 port UL PTRS for Rel.18 enhanced DMRS ports for PUSCH with rank 1-4 pusch-rank-1-4-1Port-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-4-6h: 1 port UL PTRS for Rel.18 enhanced DMRS ports for PUSCH with rank 5-8 pusch-rank-5-8-1Port-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-4-6i: 2 port UL PTRS for Rel.18 enhanced DMRS ports for PUSCH with rank 1-4 pusch-rank-1-4-2Port-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-4-6j: 2 port UL PTRS for Rel.18 enhanced DMRS ports for PUSCH with rank 5-8 pusch-rank-5-8-2Port-r18 ENUMERATED {supported} OPTIONAL } OPTIONAL, -- R1 40-4-13: Support Rel-18 UL DMRS with single-DCI based M-TRP ul-DMRS-SingleDCI-M-TRP-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-4-14: Support Rel-18 UL DMRS with M-DCI based M-TRP ul-DMRS-M-DCI-M-TRP-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-5-5: Maximum 2 SP and 1 periodic SRS sets for 8T8R antenna switching srs-AntennaSwitching8T8R2SP-1Periodic-r18 ENUMERATED {supported} OPTIONAL, -- R1 40-6-4: Single-DCI based STx2P SFN scheme for PUCCH pucch-SingleDCI-STx2P-SFN-r18 ENUMERATED {pf0-2, pf1-3-4, pf0-4} OPTIONAL, -- R1 41-4-6: Positioning SRS bandwidth aggregation in RRC_CONNECTED posSRS-BWA-RRC-Connected-r18 PosSRS-BWA-RRC-Connected-r18 OPTIONAL, -- R1 41-4-7: Positioning SRS bandwidth aggregation independent from UL communication CA in RRC_CONNECTED posSRS-BWA-IndependentCA-RRC-Connected-r18 PosSRS-BWA-IndependentCA-RRC-Connected-r18 OPTIONAL, -- R1 41-4-9: Indicate which other bands in the band combination are affected due to the need of a guard period posSRS-BWA-AffectedBandList-r18 SEQUENCE (SIZE (1..maxBands)) OF FreqBandIndicatorNR OPTIONAL, -- R1 45-5a: RACH-based early TA acquisition with simultaneous transmission rach-EarlyTA-BandList-r18 SEQUENCE (SIZE (1..maxBandsMRDC)) OF BOOLEAN OPTIONAL, -- R1 49-6: Two HARQ-ACK codebooks with up to one sub-slot based HARQ-ACK codebook simultaneously constructed for supporting -- HARQ-ACK codebooks with different priorities by DCI format 1_3 simultaneous-2-1-HARQ-ACK-CB-r18 SubSlot-Config-r16 OPTIONAL, -- R1 49-6a: Two HARQ-ACK codebooks with two sub-slot based HARQ-ACK codebook simultaneously constructed for supporting -- HARQ-ACK codebooks with different priorities by DCI format 1_3 simultaneous-2-2-HARQ-ACK-CB-r18 SubSlot-Config-r16 OPTIONAL, -- R1 49-7: UL intra-UE multiplexing/prioritization of overlapping channel/signals with two priority levels in physical -- layer for DCI format 1_3/0_3 ul-IntraUE-MuxEnh-r18 SEQUENCE { pusch-PreparationLowPriority-r18 ENUMERATED {sym0, sym1, sym2}, pusch-PreparationHighPriority-r18 ENUMERATED {sym0, sym1, sym2} } OPTIONAL, -- R4 27-1 TxDiversity for 4Tx txDiversity4Tx-r18 ENUMERATED {supported} OPTIONAL, -- R4 41-2: Power boosting for DFT-s-OFDM pi/2 BPSK and QPSK transmissions without modified spectrum flatness requirement powerBoosting-pi2BPSK-QPSK-r18 ENUMERATED {supported} OPTIONAL, -- R4 41-3: Power boosting for DFT-s-OFDM pi/2 BPSK and QPSK transmissions with modified spectrum flatness requirement shaping powerBoosting-pi2BPSK-QPSK-Modified-r18 ENUMERATED {supported} OPTIONAL, -- R4 44-1 TxDiversity for 2Tx txDiversity2Tx-r18 ENUMERATED {supported} OPTIONAL, ue-PowerClassPerBandPerBC-v1820 ENUMERATED {pc5} OPTIONAL }